Brand Name : SIMO

Model Number : SIMO Blower 9-11

Certification : CE, ISO9001:2008,TUV

Place of Origin : Henan China

MOQ : 1 Set

Price : Negotiable

Payment Terms : T/T, L/C, Payment Term Is Negotiable

Supply Ability : 500 Sets Per Month

Delivery Time : 15-35 Days

Packaging Details : Export Wooden Case Packing, Steel pallet Packing

Feature : High Performance

Mounting : Free Standing

Drivetrain : Direct/Coupling Driven/V-belt Driven

Bearing : SKF/FAG/By your demand

Main shaft : High-strength carbon structural steel

Lubrication : Oil bath lubrication

Contact Now

Primary Air Pulverized Coal Drying Grey Centrifugal Exhaust Fan

Introduction

The 9-11 series fan has a large flow rate and moderate pressure.

This fan is designed for the purpose of using industrial boiler to work in the high-efficiency area and achieve the energy-saving target.

The Primary Air Pulverized Coal Drying Grey Centrifugal Exhaust Fan is suitable for equipped with economizer (heater) and smoke and dust removal device.

It is a high-efficiency energy-saving product jointly designed by the national fan industry and organized by the national wind power industry and the Ministry of Machinery Industry.

It has the characteristics of high efficiency, low noise, flat performance curve and wide efficient area.

Industrial boilers of 5 ~ 35 tons/hour can be used, those with similar intake conditions and suitable performance can be used, but the maximum temperature shall not more than250°C.

Before the induced draft fan, dust removal device with a dust removal efficiency of no less than 85% must be installed to reduce the dust content of the smoke entering the fan.

It can not only reduce the pollution of the smoke on the environment, but also reduce the wear of the smoke on the fan, which is conducive to prolonging the life of the fan.

Application

1. As a device with good performance, centrifugal fans are now widely used for ventilation, dust exhaust and cooling in factories, mines, tunnels, cooling towers, vehicles, ships and buildings. The role of centrifugal fans is powerful. When users choose to use them, they also need to start from the characteristics of centrifugal fans and use them in a scientific way to ensure that the fans bring greater benefits to themselves.

2. In the factory, the workshops, warehouses and other departments are equipped with centrifugal fans, which play a role in ventilation, ensure the fresh air in the workshop, and help to purify the working environment and the health of employees. At the same time, the factory warehouse is equipped with centrifugal fans to dry the air to ensure that the mechanical equipment or other industrial products maintain the original quality.

3. Install centrifugal fans in mines and tunnels to re-enter fresh air and exhaust dirty air to ensure air circulation in the mines and tunnels.Centrifugal fans can help dust discharge, ensure air transparency in mines and tunnels, and ensure the health of workers in mines and tunnels.

4. A centrifugal fan is installed in the cooling tower, which not only plays the role of ventilation and ensures the normal operation of the cooling tower, but also plays a positive role in improving the cooling effect of the cooling tower by the large flow wind generated by the centrifugal fan.

Product features

1.The fan can output higher gas pressure, and can provide more gas flow at the same time, low noise.

2. In the case of using the common base, the installation is very simple and basically does not require the support of professional technicians.

3. The motor shaft is elastically connected with the drive shaft. It is not necessary to tighten the belt or replace the belt frequently, and the maintenance workload is small.

4. The fan system running at normal temperature with an impeller diameter of less than 1400 mm does not require additional configuration of bearing cooling device, which reduces the user's investment and maintenance workload.

5. When the airflow resistance is increased, the motor load will be automatically reduced and the motor will not be burnt.

6.The fan is made of high quality carbon steel, and can also use stainless steel or other metal materials according to customer requirements.

7. Running test and vibration value detection after the production is completed, the fan operation is reliable.

Technical data

series model

Exhaust Fan

Rotation Speed
(r/min)

Exhaust Fan

Total Pressure
(Pa)

Exhaust Fan

Air Capacity
(m³/h)

Exhaust Fan

Power
(kW)

9-11 4D 2900 22852452 3297~6594 5.57.5
4.5D 2900 28933060 46959389 1115
5D 2900 35703854 644012880 1522
5.6D 2900 44824805 904818095 3045
6.3D 1450 14221500 644112882 7.511
7.1D 1450 18041942 922018439 1118.5
8D 1450 22852462 1318926378 18.530
9D 1450 28933099 1877937558 3755
10D 1450 35703854 2576042933 5590
11.2D 9601450 19614835 2396172381 30160
12.5D 730960 14122638 2532966620 2290
14D 730960 17753305 3558693596 45160
16D 730960 23144295 53120139712 75280
4D 2900 20692187 3297~6594 5.57.5
4.5D 2900 26182766 46959389 1115
5D 2900 32273413 644012880 1522
5.6D 2900 40504286 904818095 3037
6.3D 1450 12851383 644112882 5.57.5
7.1D 1450 16281746 922018439 1115
8D 1450 20692226 1318926378 18.530
9D 1450 26182824 1877937558 3055
10D 1450 32273481 2576051519 5590

FAQ

1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.

2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.

3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.

Primary Air Pulverized Coal Drying 2900r/Min Centrifugal Exhaust Fan

Primary Air Pulverized Coal Drying 2900r/Min Centrifugal Exhaust Fan

Primary Air Pulverized Coal Drying 2900r/Min Centrifugal Exhaust Fan


Product Tags:

2900r/Min Centrifugal Exhaust Fan

      

Air Pulverized Centrifugal Exhaust Fan

      

2900r/Min centrifugal exhaust blower

      
China Primary Air Pulverized Coal Drying 2900r/Min Centrifugal Exhaust Fan wholesale

Primary Air Pulverized Coal Drying 2900r/Min Centrifugal Exhaust Fan Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xinxiang SIMO Blower Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

Copyright © 2009 - 2024 bjjsgy.com. All rights reserved.